Analysis of Fire Protection System Implementation in PT. Prima Fara Textile's Finishing Building
DOI:
https://doi.org/10.59890/ijels.v3i8.115Keywords:
Active Fire Protection System, Passive Fire Protection System, Fire ManagementAbstract
Fire is a disaster event that comes from an undesired fire that can cause losses, both material losses (in the form of property, physical buildings, depots, facilities and infrastructure) and non-material losses (such as fear, trauma) to loss of life or disability caused by fire. To prevent this, the company implements a Fire Protection System, a fire prevention program with various efforts, especially in the workplace. This study aims to determine how the application of a passive fire protection system in the Finishing building at PT. Prima Fara Textile. This study is a qualitative study with an Implementation Research (IR) approach. The Finishing Building is a building where the sarong is processed from raw to cooked, in the Finishing building there are 74 employees (66 men and 8 women). The data analysis used is using checklist data according to current regulations in Indonesia. The results of the Active Protection System research are only 20% in accordance with regulations, for the Passive Protection System 90% is in accordance but there is a little lacking in this protection system, while for fire management it is 80% in accordance with existing regulations, but there must be training for all employees so that everyone in the PT knows about fire management. The suggestion for this research is to complete what is required in the fire management regulations so that there are no unwanted incidents.
References
Anwar, H. A. (2023). Evaluation of a passive protection system against fire hazards in the Makassar Private Care Center (PCC) building. 1-45.
Gogendra, G., & Andriyani, A. (2021). Analysis of the application of passive fire protection systems and rescue facilities in the efforts of the emergency response plan at the Jakarta Eye Center in 2020. Environmental Occupational Health and Safety Journal, 1 (2), 129. https://doi.org/10.24853/eohjs.1.2.129-142
PU Kepmen. (2000). Decree of the State Minister of Public Works No. 10/KPTS/2000 concerning Technical Provisions for Security of Fire Hazards in Buildings and Environment. Department of PU, 177.Performance.lib.itb.ac.id/arsitek/index.php/bibliography/detail/6210
Minister, P., & General, P. (2008). Minister of Public Works Regulation No. 26/PRT/M/2008 concerning Technical Requirements for Fire Protection Systems in Buildings and Environment.
Musyafak, A. M. H. (2020).Fire management system in hospitals. Higeia Journal of Public Health Research and Development, 4 (1), 158–169.
Republic, I. K. (2023). https://dataindonesia.id/varia/detail/kasus-kebakaran-di-indonesia-cetak-recor-pada-juni-2023.
Law Law Number 24 of 2007. (2007). No titleымымыв. Legislation, 1 (235), 245. Http://digilib.unila.ac.id/4949/15/bab II.pdf
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Mohammad Triyanto, Ristiawati, Jaya Maulana

This work is licensed under a Creative Commons Attribution 4.0 International License.